Nexsus 7K module Trouble-shooting Commands
Powering On or Off Specific Module :
config # poweroff module 5 # for power off
config # no poweroff module 5 # for poweron module
power redundancy-mode
power redundancy-mode {combined | insrc-redundant | ps-redundant | redundant}
no power redundancy-mode {combined | insrc-redundant | ps-redundant | redundant}
show diagnostic result module 18
show module
tac-pac bootflash:tech.txt show tech module 1 show tech gold show hardware internal errors module 1 | diff - issue this a few times
# show diagnostic result module 1 # diagnostic clear result module all (config)# no diagnostic monitor module 1 test 5
(config)# diagnostic monitor module 1 test 5 # diagnostic start module 1 test 5 # show diagnostic result module 1 test 5
Note: It could take a few minutes before the test is completed.
# show module internal exceptionlog module 1 # show module internal event-history errors # show hardware internal errors module 1
diagnostic start module 2 test
Show version
Show system reset-reason
show core